Home

DePuy cemented hemiarthroplasty

cemented THOMPSON Hemiarthroplasty is indicated if the uncemented prosthesis was unstable, if there was an intra-operative fracture, or in cases of previously undiagnosed metastatic disease. NOTE: If a cemented THOMPSON is used, please follow guidelines of your cement supplier and be aware of local guidelines for use of hemi-arthroplasty products TECHNIQUES IN CEMENTATION FOR HIP HEMIARTHROPLASTY 7 VOLUME 26, JUNE 2016 Discussion Cemented hip hemiarthroplasty is a technically challenging but useful technique for the treatment of osteoporotic intracapsular hip fractures. In this subset of patients with increased medical comorbidities, there are several implications of this technique

Summit Cemented Hip System - Cemented Femoral Stem Surgical Technique. COVID-19. Our thoughts are with everyone affected by the Coronavirus. Throughout this rapidly evolving situation, the health and well-being of our staff, business partners, and our customers are our priority. We've instituted a pandemic plan across our organization that. Intervention: Uncemented Bipolar Hemiarthroplasty-115 hips (Corail stem, DePuy Johnson and Johnson) with a mobilecup, Mean age: 83 years, 62% died at 5 years follow up Comparison: Cemented Bipolar Hemiarthroplasty-115 hips (Spectron, Smith and Nephew), Mean age: 83.4 years, 61% died at 5 years follow up Follow up: 5 years after surgery (range. to bone without the use of bone cement.3 With more than 30 years of clinical heritage, our proprietary POROCOAT Porous Coating is composed of commercially pure titanium sintered metal beads. Design Rationale & Surgical Technique SUMMIT® Tapered Hip System DePuy Synthes Companies

Introduction. A hemiarthroplasty is an operation that is used most commonly to treat a fractured hip. The operation is similar to a total hip replacement, but it involves only half of the hip. (Hemi means half, and arthroplasty means joint replacement.)The hemiarthroplasty replaces only the ball portion of the hip joint, not the socket portion No available references for this page. 125071-201001 DSUS. Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions The Summit™ Cemented Hip System follows the classic Charnley heritage while incorporating advancements in stem design, which address enhanced torsional stability, greater offset options and optimized cement mantle. Cobalt chrome alloy was selected for the component as its greater rigidity transmits stress more evenly throughout the cement mantle A hemiarthroplasty is a surgical procedure that involves replacing half of the hip joint. Hemi means half and arthroplasty refers to joint replacement. Replacing the entire hip joint.

Learn the Total Hip replacement: C stem AMT/Elite (Depuy) cemented hip (femur first) surgical technique with step by step instructions on OrthOracle. Our e-learning platform contains high resolution images and a certified CME of the Total Hip replacement: C stem AMT/Elite (Depuy) cemented hip (femur first) surgical procedure • Reduced proximal geometry monobloc humeral stem for cemented application Design based on the success of the Delta CTA™ Reverse Shoulder means that the Delta Xtend™ System is the next step forward for appropriate management of patients with Cuff Tear Arthropathy. The Delta Xtend™ System allows you to treat more patients, effectively Loaded Acrylic Cement, or the Prostalac® (prost-allik) Hip Temporary Prosthesis System, was developed to function temporarily as a total hip replacement (THR). It was also designed as a carrier device for local delivery of antibiotic drugs within th In cemented hemiarthroplasty, The decision was made to use a cemented size 4 implant. A cement restrictor was placed and DePuy CMW 1 Bone Cement (DePuy Synthes, Warsaw, IN), a high-viscosity medium-setting-time polymethylmethacrylate cement, was pressurized into the canal after it had reached medium-to-high viscosity.. Hemiarthroplasty is a surgical procedure that replaces one half of the hip joint with a prosthetic, while leaving the other half intact. There are several different options available for the type of device to be used; we prefer to use a bipolar type, which has a femoral head that swivels during movement

9 Cemented A Uncemented Z No Qualifier 27125 Hemiarthroplasty, hip, partial (eg, femoral stem prosthesis, bipolar arthroplasty) C -- NA 27130 Arthroplasty, acetabular and proximal femoral prosthetic replacement (total hip arthroplasty), with or without autograft or allograf Purpose: The treatment of choice for a displaced femoral neck fracture in the most elderly patients is a cemented hemiarthroplasty (HA). The optimal design, unipolar or bipolar head, remains unclear. The possible advantages of a bipolar HA are a better range of motion and less acetabular wear Although advocates for cemented hemiarthroplasty focus on the decreased intraoperative and postoperative periprosthetic fracture (PPF) risk, uncemented hemiarthroplasty advocates highlight the reduced operative time and absence of morbidity or mortality attributable to BCIS. [DePuy], Warsaw, IN) from January 2008 to December 2018 were.

Summit Cemented Hip System - Cemented Femoral Stem

arthroplasty with cementless and cemented applications for rehabilitating hips damaged as a result of: • Advanced wear of the joint due to degenerative, post-traumatic, or rheumatic diseases. • Failed previous hip surgery including joint reconstruction (osteotomy), arthrodesis, hemiarthroplasty or total hip replacement (THR) In cemented hemiarthroplasty, polymethylmethacrylate bone cement is used to DePuy Summit (DePuy Synthes, Warsaw, IN) cemented stem was placed along with a 45-mm þ 0 unipolar head. On final testing, the hip demonstrated appropriate stability throughout intraoperative examination. The soft tissue sleeve and skin were closed, and th

Cemented Vs Uncemented Femoral Stems in Fracture Neck of

Patients with uncemented hemiarthroplasty, however, had lower mortality at days 0 and 1 than patients with cemented hemiarthroplasty (HRR, 0.4; CI, 0.3-0.5; p < 0.001) . For the remainder of the patients' lifetimes, as well as in aggregate, there were no differences in mortality ( Fig 4 ) FACT FILEAge: 83 years, Sex femaleHistory: Untreated basotrochanteric fracture of one month duration.Procedure: Monopolar cemented hemi arthroplasty.Implant. Patients underwent a bipolar hemiarthroplasty with either a cemented femoral stem (Spectron; Smith & Nephew, Memphis, TN, USA) (Fig. 2) or an uncemented femoral stem (Corail; DePuy/Johnson and Johnson, Leeds, UK) (Fig. 3). The cemented stem is a straight, collared stem made of a cobalt-chromium alloy. Its proximal one-third is grit-blasted A cemented prosthesis is held in place by a type of epoxy cement that attaches the metal to the bone. An uncemented prosthesis bears a fine mesh of holes on the surface that allows bone to grow into the mesh and attach the prosthesis to the bone. Both methods are still widely used. The decision about whether to use a cemented or uncemented prosthesis is usually made by the surgeon based on. Hemiarthroplasty of the hip is standard treatment of femoral neck fractures (hip fractures). Hemiarthroplasty means replacing the hip joint with a metal prosthesis. Unipolar prostheses has a one-piece design where the hip movement occurs between the prosthesis and the acetabulum (hip socket)

Hemiarthroplasty of the Hip Orthogat

Patients underwent a bipolar hemiarthroplasty with either a cemented femoral stem (Spectron; Smith & Nephew, Memphis, TN, USA) or an uncemented femoral stem (Corail; DePuy/Johnson and Johnson, Leeds, UK) . The cemented stem is a straight, collared stem made of a cobalt-chromium alloy. Its proximal one-third is grit-blasted Resurfacing hemiarthroplasty of the femoral head has been recommended as a bone-preserving alternative to total hip arthroplasty for the management of osteonecrosis of the femoral head in the young patient. This case report describes failure of a cemented resurfacing hemiarthroplasty resulting from a fracture through the stem of the implant

Hip Replacement Prosthesis J&J Medical Device

  1. Hip replacement is a surgical procedure in which the hip joint is replaced by a prosthetic implant, that is, a hip prosthesis.Hip replacement surgery can be performed as a total replacement or a hemi (half) replacement. Such joint replacement orthopaedic surgery is generally conducted to relieve arthritis pain or in some hip fractures.A total hip replacement (total hip arthroplasty or THA.
  2. Patients aged 80 years and older operated with an cemented hemiarthroplasty. Fixation of the wedge-shaped, polished ChromCobalt steel femoral stem to host bone by use of PolyMetylMetAcrylat bone cement. The acetabulum is not replaced. The prosthesis articulates with the patients acetabulum with an unipolar, femoral head made of ChromCobalt steel
  3. Metal/Ceramic/Polymer, Cemented or Non-porous Uncemented. Defuy Quantum Hip Stem DePuy Modular Press-Fit (MPF) Hip (Std. & MMA> DePuy Vision AML Hip Stems DePuy AML MMA Hip Stem DEVICE DESCRIPTION: The Response 2000 Hip Stem is manufactured from ASTM F-75 Co-Cr-Mo alloy. It is
  4. Intervention. Patients underwent a Charnley-Hastings bipolar cemented hemiarthroplasty (DePuy/Johnson and Johnson, United Kingdom) or closed reduction and internal fixation with two parallel cannulated screws (Olmed, DePuy/Johnson and Johnson, Sweden).11 Arthroplasty was performed through a direct lateral approach12 with the patient in a lateral decubitus position with a third generation.
  5. Cement-in-cement femoral revision. An 84-year-old man presented with a displaced femoral neck hip fracture ( A ) and underwent a cemented, bipolar hemiarthroplasty ( B ).The surgery was complicated by recurrent anterior dislocation ( C ).Revision of the femoral component used a tap-out, cement-in-cement technique ( D ).A shorter and smaller-sized, polished, collarless, tapered stem was used.

Hemiarthroplasty: Procedure, Recovery, Complications, and Mor

The latest design of taper slip stems, such as the C-stem (DePuy Orthopaedics, Warsaw, Ind), may have advantages in maintaining proximal bone stock and preserving host bone. Cemented hip. However, an adverse cardiovascular event has been associated with cemented hemiarthroplasty and this is sometimes referred to as 'bone cement implantation syndrome' (BCIS) 6. Adverse cardiovascular events occur in approximately 20% of hip fracture operations in which a cemented prosthesis is used 1, 2 ECHELON Revision Cemented implants are part of a family of femoral stems that address primary and revision situations. With one set of instruments, a variety of stems can be implanted. System Features. Double Taper Proximal Geometry-Limits shear stresses and promotes compressive stress transfer between the cement and implant

A cemented joint replacement attaches the joint to the bone with epoxy cement. An uncemented joint prosthesis has a mesh of holes on its surface that allows the growth of the patient's natural bone to hold the device in place. As stated in Section A11 of the ICD-10-PCS guidelines, Many of the terms used to construct PCS codes are defined. For the qualifier (character 7), the choices include cemented, uncemented, or no qualifier. For example, a left total hip arthroplasty using a cemented stem and a metal-on-plastic articulating surface is classified to code 0SRB029. Replacement includes taking out the body part (eg, hip joint)

A Prospective Randomized Trial of Uncemented Versus Cemented Hemiarthroplasty for Displaced Femoral Neck Fractures (HEMI04) Other Name: Corail, DePuy/Johnson and Johnson, United Kingdom. Active Comparator: Cemented Cemented primary bipolar hemiarthroplasty of the hip cemented hemiarthroplasty used in the treatment of displaced fractures of the femoral neck AN OBSERVATIONAL STUDY OF 11 116 HEMIARTHROPLASTIES FROM A NATIONAL REGISTER J-E. Gjertsen, S. A. Lie, T.

Total Hip replacement: C stem AMT/Elite (Depuy) cemented

  1. It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, and to articulate with an acetabulum prosthesis as part of a total hip arthroplasty (THA), or articulate with the natural acetabulum directly or via a bipolar component as part of a partial hip arthroplasty (hemiarthroplasty)
  2. StEP 3 4 ACCOLADE II SurgICAL tECHnIquE 5 The ACCOLADE II Hip System is a broach only system. While use of an axial starter reamer is needed, use of cylindrical reamers is not necessary to prepare the femora
  3. 4 DePuy Synthes Joint Reconstruction CORAIL Design Rationale arthrodesis, hemiarthroplasty, or total hip replacement. 5. Certain cases of ankylosis. • HA coated implants must not be implanted with cement • When changing the head on a femoral stem which is still in place, it is essentia
  4. Unipolar hemiarthroplasty (, Fig 14) is used in elderly patients with lower life expectancy for treatment of intracapsular hip fractures. The unipolar prosthesis consists of a press-fit or cemented component with a head diameter that matches that of the acetabulum and articulates directly with the acetabular articular cartilage (, 1 3 4)
  5. surgeons who prefer to perform hemiarthroplasty or total hip arthroplasty operations while avoiding bone cement. The Interlok surface promotes secure bone on-growth fixation, while the metaphyseal fins allow for additional rotational stability and fixation. Reduced Proximal Profile Optimal fit for Type C or stove pipe canal often associate
  6. Conclusion In recurrent dislocation of hemiarthroplasty in elderly, a total 8.2 24.8 17.6 2.6 (%) hip replacement using a cemented constrained acetabular cup com- -

A cautionary tale of the Charnley-Hastings bipolar hemiarthroplasty M.J. Reid*, P.A. Butler-Manuel Orthopaedic Surgery Department, Conquest Hospital, The Ridge, St Leonards-on-Sea, East Sussex TN37 7RD, United Kingdom The trial prosthesis was inserted easily and so a cement restrictor (DePuy). The batch with the same lot numbe Cemented bipolar hemiarthroplasty commonly is used to treat displaced fractures of the femoral neck in elderly patients. The purpose of the current study was to review the results and survivorship of 212 bipolar hemiarthroplasties done in 205 patients for acute femoral neck fracture between 1976 and 1985 Removal of the Cemented Humeral Body . . . .26 Washington, University of Pennsylvania and DePuy Orthopaedics, Inc., Warsaw, Indiana. The challenges encountered by shoulder arthroplasty surgeons include surgical exposure, soft tissue hemiarthroplasty to a total arthroplasty. The Techniqu An earlier Cochrane review28 that compared cemented and cementless arthroplasty and internal fixation also carried out a meta-analysis of total hip arthroplasty compared with hemiarthroplasty based on three studies used in this review.45 47 50 The Cochrane review found no significant differences between the interventions, although there was a.

Hip Hemiarthroplasty (Unipolar / Bipolar) September 10, 2017. September 10, 2017. TodaysOR. Hemiarthroplasty of the Hip means that only half of the hip joint wil be replaced (hemi = half / partial). Hemiarthroplasties are done for pt.s who have a femoral neck fracture (displaced femoral head) where the blood supply the the femoral head has been. Event Description. I had a depuy hip replacement on my left hip in (b) (6) 2005. The device used was a summit stem with a pinnacle cup (metal-on-metal, non-cemented). I have never had full mobility and beginning in (b) (6) 2010, i began to experience groin pain which progressed to the buttocks and then to the area of the hr incision

DePuy Excel Fracture System Bi-Polar Head, Self-Centering (Hip) 28mm ID 44mm OD. Part # 1035-44-000 Exp 5/09. Note: This item is the head/ball portion only of the hip and is part of the Excel Fracture System. We have 95% of the system in stock. This product is best purchased by a facility already using the system or familiar with it results of cementless bipolar hemiarthroplasty for unstable intertrochanteric fractures in elderly patients. Methods: Forty hips were followed for more than 2 years after cementless bipolar hemiarthroplasty using a Porocoat® AML Hip System. The mean age was 78.8 years and the mean follow-up period was 40.5 months

DePuy (J and J) PFC Cemented - OrthopaedicsOne Device

hemiarthroplasty. The major-ity of patients were treated with cemented components, with a 20% rate of complica-tions. At 5 years postopera-tively, 89% of the surviving patients reported mild or no pain and 91% continued to ambulate (45% unassisted). Five patients reported moder-ate or severe pain in the region of the greater trochanter, and DePuy Delta Reverse and Tornier Aequalis Reverse. DePuy Delta Reverse: The Use of the Reverse Shoulder Prosthesis for the Treatment of Failed Hemiarthroplasty for Proximal Humeral Fracture: This adapter fits on the Modular cemented, cemented, press fit and fracture stems. Zimmer Anatomical Reverse As indicated in the parenthetical note immediately following code 27125, the appropriate code to report prosthetic hip replacement (eg, bipolar arthroplasty) following fracture of the hip, is 27236, Open treatment of femoral fracture, proximal end, neck, internal fixation or prosthetic replacement (direct fracture exposure). J Total Shoulder Replacement- In this operation the rough arthritic ball is replaced with a smooth metal ball, and the rough socket is covered with a smooth plastic socket that is cemented into place. Now we have two smooth surfaces like in a normal shoulder. Hemiarthroplasty- This means half replacement

cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck. Patients and Methods From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included Cement) functional spacer is made with antibiotic-loaded acrylic cement. We use it as an interim spacer in two-stage exchange arthroplasty in cases of infected total knee or total hip replacement. PROSTALAC allows continuous rehabilitation between stages as it maintains good alignment and stability of the joint with a reasonable range of movement

Patients were operated with a hemiarthroplasty using an uncemented press-fit hydroxyapatite-coated femoral stem (Corail, DePuy Orthopaedics Inc, Warzaw, IN, USA). The BHA group received a 28 mm cobalt chromium head and a bipolar head (Self-Centering™ Bipolar, DePuy Orthopaedics Inc, Warzaw, IN, USA) Hemiarthroplasty implant data are not recorded in the National . Joint Registry (NJR), so this year we asked hospitals to indicate the types of implant they usually used, and those which they occasionally employed (Fig 3). 95% of hospitals reported cemented implants as their prosthesis . of choice. There was, however, significant variation in. In rare cases, bone cement may fragment and cause joint to loosen or may leak bone marrow, fat or cement into the bloodstream which can cause a serious complication known as Bone Cement Implantation Syndrome (BCIS). Notable bone cement manufacturers include Johnson & Johnson's DePuy orthopedics unit, Biomet Zimmer ant others

Deep Vein Thrombosis after Cement Intravasation during Hip

Hip Bipolar Hemiarthroplasty for Femoral Neck Fractur

All patients who had undergone hemiarthroplasty surgery through a direct lateral or posterior surgical approach were selected. To have a homogenous group, patients with unipolar prostheses, with cemented prostheses fixed with non-antibi-otic-loaded cement, with pathological fractures, with extra Description. From Which Medical Device . The Summit® Cementless Hip Replacement System from Depuy-Synthes is a tapered cementless titanium hip stem, whose features include a tapered neck geometry, a Porocoat porous or DuoFix HA coating, an anatomical medial curve, a grit blasted diaphyseal region and a polished distal tip to reduce cortical impingement Hip. Implants. We offer market-leading hip replacement implants for total hip arthroplasty, including our primary and revision portfolios designed to offer you a wide variety of implants, instrumentation and muscle-sparing surgical approach options

DePuy Orthopaedics is a subsidiary of Johnson & Johnson.The company, founded in 1895, merged with Synthes in 2011 to become DePuy Synthes. It has more than 200 orthopedic products, including hip, knee and shoulder replacements Comparative Study of Bipolar Hemiarthroplasty for Femur Neck Fractures Treated with Cemented versus Cementless Stem Jung-Yun Choi, MD, Yerl-Bo Sung, MD, PhD, and Joo-Hyung Kim, MD Department of Orthopedic Surgery, Inje University Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea

Bipolar hemiarthroplasty for subcapital fracture of the femoral neck: a prospective randomised trial of cemented Thompson and uncemented Moore stems. J Bone Joint Surg [Br] 1991;73-B:322-324. 10. Luo X, He S, Li Z, Huang D. Systematic review of cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures in older patients Hemiarthroplasty involved prosthetic replacement of the femoral head and fixation via bony growth into a porous-coated implant (uncemented) or with cement. Median patient age was 83 years, 69.3% were women, and 48.4% had uncemented and 51.6% cemented fixation DePuy's hip implants are an excellent example of this happening in real life. of the pelvis and the femoral head of the femur in a total hip arthroplasty procedure or just the femoral head in a hemiarthroplasty where it is held in place as a ball-and-socket joint. This joint is either screwed or cemented in place on the inside of the.

Description. The C-stem AMT (Articul/Eze 12/14 mini taper) total hip system from Depuy is a triple-tapered polished cemented stem for use in primary hip arthroplasty. As with other systems, the third taper runs from narrow medial to broad lateral, with the aim of improving load transfer proximally and improving rotational stability GMDN Preferred Term Name GMDN Definition; Bipolar femoral head outer component, hemiarthroplasty An implantable hemisphere-shaped device used as part of a partial hip replacement (femoral) and designed to interface with the acetabulum on its outer surface where it freely rotates, and interface with a femoral head prosthesis on its inner surface where it allows free rotation of the head

Depuy Global Advantage CTA head was used in 5 cases and Biomet Bio-Modular EAS head was used in one case. All prosthesis were non-cemented types. Patients were evaluated based on JOA scores, range of motion, and X-P. Patient follow-up averaged 25.3 months (ranged 12-36 months) hemiarthroplasty. Figure 2. Anteroposterior radiograph of the left shoulder shows a polyethylene (keeled) glenoid compo-nent (Total Polyethylene glenoid; DePuy, Warsaw, Ind) used in a total shoulder arthroplasty. 1296 September-October 2003 RG f Volume 23 Number 5 RadioGraphic Christie J, Robinson CM, Singer B, et al. Medullary lavage reduces embolic phenomena and cardiopulmonary changes during cemented hemiarthroplasty. J Bone Joint Surg Br . 1995; 77:456-459. Morgan J. Cemented Vs Uncemented Femoral Stems in Fracture Neck of Femur Cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures: 5-year followup of a randomized trial. Langslet E1, Frihagen F, Opland V, Madsen JE, Nordsletten L, Figved W THE REMEDY® KNEE SPACER is part of the treatment foreseen in a two-stage procedure performed in the event of permanent prosthesis infection. The REMEDY® Knee Spacer implant is intended for temporary use only (180 days or less). It allows basic joint mobility and releases antibiotics into the joint area to protect the implant from bacterial colonization

Unipolar hemiarthroplasty versus bipolar hemiarthroplasty

sociation (NARA) project a common hemiarthroplasty dataset has been established. 36,989 pri-mary hemiarthroplasties (HAs) for acute hip fractures reported to NHFR (n = 12,761) and SHAR Charnley Modular(DePuy) Hastings (DePuy) Cemented Bipolar 810 (6.4) Titan (DePuy) Cupule Mobile (DePuy) Cemented Bipolar 697 (5.5 Reverse Hemiarthroplasty for Staged Revision to Reverse Shoulder Arthroplasty. A 65-year-old female patient presents with a painful and dysfunctional right shoulder 14 years after anatomic total shoulder arthroplasty and subsequent glenoid component removal for aseptic loosening The UHMWPE cement restrictor is intended for use in cemented total and hemiarthroplasty procedures to restrict distal flow of bone cement in the femoral medullary cavity. Type/model/article number: 546010000, 546012000, 546014000, 546016000, 546018000, 546020000, 546022000: Notified body: 2797 0086 (Kehtis kuni 03.11.2020) Manufacturer: DePuy. 10CInsert Cement Thoroughly clean and dry the canal. Insert a bone plug to a level 2cm distal to end of stem. Prepare the bone cement. Pump cement into the canal in retrograde fashion, retracting the nozzle as back pressure is felt (Figure 10C). When the canal is filled with cement, place the appropriate pressurizing seal in the mouth of femur DePuy. DePuy, which has consolidated with Synthes, is apart of Johnson & Johnson Companies. Founded in 1895, DePuy was the first commercial orthopaedics company in the USA. In total, DePuy has more than 200 products used for joint replacement surgery. Acetabular Components. PINNACLE® Hip Solutions-Offers a wide variety of shells and liners.

6 Surgical Technique SMR™ PRIMARY SMR™ PRIMARY SURGICAL TECHNIQUE Indications, contraindications and warnings INDICATIONS The SMR™ Shoulder System is intended for partial or total, primary or revision shoulder joint replacement. The SMR ™ Anatomic Shoulder System is indicated for partali or total, primary or revision shoulder joint replacement in patient Hemiarthroplasty has been the treatment of choice in patients with bone quality and fracture patterns not amenable to open reduction and internal fixation. Reverse total shoulder arthroplasty is a newer option that appears to be less dependent on tuberos-ity healing than hemiarthroplasty. The authors hypothesized that reverse total shoulde Cementless bipolar hemiarthroplasty using the anatomic medullary locking (AML) femoral stem (Depuy, Warsaw, IN, USA) was performed on forty-five patients with intertrochanteric fractures, aged 70 and over, and were able to walk either with or without an aid prior to surgery at our institution between January 2000 and December 2005

Does Proximal Femoral Morphology Impact Morbidity and

The aim of this study was to describe patient-reported outcome measures of revision surgery from failed uncemented Global CAP (DePuy, Warsaw, Indiana) resurfacing hemiarthroplasty to total shoulder or reverse shoulder arthroplasty. Eleven patients from 2 collaborating institutes had a failed resurfacing prosthesis increased with. prolonged in vivo implantation >8yr. pressure. temperature. has lower heat conductivity than alumina (joint temperature can reach 99oC for zirconia, and 50oC for alumina) Titanium on Polyethylene. not recommended due to high wear rates. Flashcards (2) THA Prosthesis Design bearing surfaces Methods: In the period from September 2010 to July 2012 I have done 23 cases of revision hip arthroplasty for complicated hip hemiarthroplasty using cementless modular long stems in all cases and cementless cups in 19 case and cemented cups in 4 cases. I used wagner osteotomy to remove cement from the femoral medulla in 17 cases while 6 cases. The most popular uncemented stem was the Corail® (DePuy, Warsaw, IN, US) .11 A meta-analysis published in 2010 did not show any difference in mortality or incidence of deep infection between cemented hemiarthroplasty and total hip replacement at one year.5

THA Prosthesis Design - Recon - OrthobulletsAvens Publishing Group - Reasons for Early Failure in

If cement was used in the primary total hip replacement, this is removed, as well. Removing this cement from the bone is a time-consuming process that adds to the complexity and length of the revision surgery. Occasionally, a controlled fracture of the femur (thighbone) will be performed in order to remove a well-fixed stem. The femur will be. Joint Arthroplasty Devices Market by Procedure Type (Value and Volume) - Ankle Arthroplasty; Elbow Arthroplasty (Total Elbow Replacement, Hemiarthroplasty); Hip Arthroplasty (Total Hip Arthroplasty - Cemented Hip Arthroplasty, Cementless Hip Arthroplasty, Hybrid Hip Replacement, Partial Hip Arthroplasty, Hip Resurfacing, Revision Hip Surgeries); Knee Arthroplasty (Total Knee Arthroplasty. Most patients (177, 96%) were operated on with a bipolar cemented hemiarthroplasty using gentamicin cement (Charnley stem (176 cases) and Elite plus stem (1 case); DePuy International Ltd., Leeds, UK). An uncemented stem was implanted in 4 patients (Corail; DePuy International Ltd, Leeds, UK)